Konferans 2010-2019 yılları
Permanent URI for this collection
Browse
Browsing Konferans 2010-2019 yılları by Metarial Type "presentation"
Now showing 1 - 7 of 7
Results Per Page
Sort Options
Item Accelerator based fast radiography system for the non destructive analysis and some applications in Turkey(IAEA, 2014-07-23) Bıyık, Recep; Kam, Erol; 0000-0001-7929-4395; TAEK-ÇNAEMDifferent radiography imaging techniques such as x, gamma and neutron grapy are well established techniques for the nondestructive testing (NDT) of materials. But Fast Neutron Radiography (FNR) is relatively new and is being developed. Using this technique all materials such as high density metals, loaded plastics, cadmium, lead, tungsten, concrete etc. can be analyzed. Compare to the other techniques fast neutrons enable non-destructive testing of thicker object The FNR studies were initiated in Turkey at 2007. The aim of this project was to set up a portable fast neutron radiography (FNR) system and to test it for use in nondestructive testing of different composite materials. In the fast neutron radiography systems accelerator based neutron generators are used which requires a particle accelerator and a target. Proton or deuteron beam is accelerated to the desired energy and bombards the target material to produce fast neutrons by a nuclear reaction. DT neutron source was used fusion of a deuterium and a tritium atom (D + T) results in the formation of a He-4 ion and a neutron with a kinetic energy of approximately 14.1 MeV. In this study we have only demonstrated a portable digital fast neutron radiography system and some images of the different composite materials to show efficiency. Experiments were carried out by using fast portative neutron generator Thermo Fischer MP320 and Low Energy Ion Accelerator Sames T400 at Çekmece Nuclear Research and Training Centre.Item Bezelye (Pisum ativum)’nin C vitamini, renk ve protein yapısı gibi önemli kalite kriterleri üzerine ışınlamanın etkisi(Gıda Teknolojisi Derneği, 2016-10) Aylangan, Ayça; Özyardımcı, Berna; İç, Erhan; TAEK-SANAEMÜlkemiz açısından ekonomik öneme sahip tarımsal ürünlerin ticaretinde ve özellikle ihracatta böceklenmeden kaynaklanan büyük problemler yaşanmaktadır. Taze meyve ve sebzelere uygulanacak çok düşük ışınlama dozları ile böceklenme kontrol altına alınabilmektedir. Bu nedenle ülkemize özgü daha fazla gıda ürünü ve böcek türünde çalışma yapılması, potansiyel ürünlerin ışınlama dozuna karşı duyarlılık düzeyinin tespit edilmesi önemli görülmektedir. Bu amaçla bezelye örneklerinde (Pisum sativum) 3 farklı ışınlama dozunun (0.25, 0.50 ve 1.00 kGy) C vitamini, renk ve proteinlerin ikincil yapısı üzerine etkisi incelenmiştir. Örneklerden C vitamini ekstraksiyonunda Hızlandırılmış Çözücü Ekstraktörü (Accelerated solvent extraction-ASE) kullanılmış ve ekstraktlar HPLC (Yüksek performans sıvı kromatografisi) kullanılarak analiz edilmiştir. Renk değerleri Minolta Spektrofotometresi ile proteinlerin ikincil yapıları ise Azalan Tam Yansıma Fourier Dönüşüm Kızılötesi (ATR-FTIR) Spektroskopisi ile analiz edilmiştir. Işınlanmamış kontrol örneği ile kıyaslandığında ışınlanmış örneklerdeki C vitamini miktarı ışınlama dozu artıkça azalma göstermiştir. Işınlama dozlarının bezelye örneklerinin L* (parlaklık), b* (sarılık) ve chroma (renk yoğunluğu) değerlerine etkisi istatistik olarak önemli (p>0.05) değildir. Ancak, örneklerin yeşil rengini tanımlayan negatif a* değerleri ışınlama dozlarından istatistik olarak önemli (p<0.05) şekilde etkilenmiştir. Proteinlerin ikincil yapılarını oluşturan α-sarmal ve β-düzlemsel tabakada ATR-FTIR ile yapılan inceleme sonucunda uygulanan düşük ışınlama dozlarının önemli bir değişime yol açmadığı belirlenmiştir.Item Burnup calculations of TR-2 research reactor with monteburns Monte Carlo code(2012-09-25) Özdemir, Levent; Erdoğan, Adem; Şentürk Lüle, Senem; TAEK-ÇNAEMIn this study, some neutronic calculations of first and second core cycles of 5 MW pool type TR-2 Research Reactor have been performed using Multi-Step Monte Carlo Burnup Code System MONTEBURNS and the results were compared with the values of experiments and other codes. Time dependent keff distribution and burnup ratios belong to first and second core cycles of TR-2 Research Reactor were compared and quite good consistence in the results were observed. After modeling the first and second core cycles of TR-2 with MCNP5 Monte Carlo code, MCNP5 used in MONTEBURNS code has been parallelized in 8 HP ProLiant BL680C G5 systems with 4 quad-core Intel Xeon E7330 CPU, utilizing the MPI parallel protocol and simulations were performed on the 128 cores Linux parallel computing machine system. The computation time was reduced by parallelization of MONTEBURNS which uses MCNP in many steps.Item Işınlama ve ESR(Selçuk Üniversitesi, 2013-11-20) Bıyık, Recep; 0000-0001-7929-4395; TAEK-ÇNAEMElektron Spin Rezonans (ESR) veya diğer adı ila Elektron Paramanyetik Rezonans (EPR) Spektroskopisi tekniği çok farklı disiplinlerde uygulama alanı bulmaktadır. Radikalin var olduğu veya çeşitli fiziksel veya kimyasal süreçlerde radikalin ortaya çıkabileceği yapıların en iyi analiz yöntemi ESR analiz yöntemidir. Radikalin bir yapı içerisinde oluşma süreçlerinde en önemli faktör maruz kaldığı fiziksel veya kimyasal etkilerdir. Radyasyon da bu etkilerin başında gelir. ESR ile radyasyonun madde veya canlı dokular üzerindeki etkisi incelenebilmektedir. Özellikle ESR tabanlı dozimetrik malzeme geliştirme, ışınlanmış gıda deteksiyonu, EPR dating çalışmaları radyasyonun direk müdahil olduğu ESR çalışmalarıdır. Düzenlencek olan çalıştayda Işınlama ve ESR başlıklı bir sunum sunulacak olup yukarıda bahsedilen konular üzerinde tartışmalara katılım sağlanacaktır.Item Radyasyonun madde ile etkileşimi. Radyasyon kaynakları(Selçuk Üviversitesi, 2017) Bıyık, Recep; 0000-0001-7929-4395; TAEK-ÇNAEMElektromanyetik radyasyon, radyo dalgası bölgesinden başlayıp gama ve kozmik ışınlara kadar uzanan ve enerjileri nano eV ile milyon eV aralığında değişen geniş bir bölgeyi kapsamaktadır. Elektromanyetik radyasyonun madde ile etkileşimi, radyasyonun türü ve miktarı ile maddenin fiziksel ve kimyasal özelliklerine sıkıca bağlıdır. Genel olarak radyasyon sınıflandırılırken enerjilerine göre iyonlaştırıcı ve iyonlaştırıcı olmayan, türlerine göre parçacık tipi, dalga tipi veya doğal radyasyon ve yapay radyasyon gibi tanımlamalar kullanılmaktadır. Radyasyon sahip olduğu enerjiye bağlı olarak madde ile etkileşimi farklılık gösterir. Etkileşme mekanizması, etkileşme olasılığı ve enerji kaybı gelen radyasyonun yüküne, enerjisine girdiği ortamın atom numarasına ve ortamın yoğunluğuna bağlı olarak değişir. Radyasyonun bir canlı organizma ile etkileşmesi durumunda biyolojik etkileri belirleyen temel faktörler ise radyasyona maruz kalma süresi, maruz kalınan toplam doz, maruz kalınma şekli (iç ve dış ışınlanma), radyasyonun türü ve enerjisidir. Doğal radyasyonun en önemli kaynağı yerküremizdir. Ortam radyasyonu (doğal background) temel olarak, yerkabuğunun neden olduğu Uranyum-238, Toryum-232, Radyum-226, Radon-222, Potasyum-40 ve kozmik ışınların neden olduğu Karbon-14, Trityum-3, Berilyum-7 gibi radyoizotop kaynaklıdır. Bununla birlikte yapay radyasyon kaynakları çok daha farklılaşmış olup günümüzde endüstriyel, tıbbi, tarım, güvenlik, eğitim ve araştırma amaçlı birçok sektörde yaygın olarak kullanılmaktadır.Item The portable fast neutron radiography system for the non destructive analysis(8-th International Conference Nuclear and Radiation Physics, 2011) Bıyık, Recep; Kam, Erol; 0000-0001-7929-4395; TAEK-ÇNAEMThe aim of this research is to set up a portable fast neutron radiography (FNR) system and to test it for use in non destructive testing of different composite materials. FNR systems provide distinctive advantages in non-destructive evaluation of thick composite materials. Other traditional techniques, such as X-ray, gamma ray and thermal neutron radiography do not meet FNRs capabilities in this area. The FNR images are produced directly during exposure; the neutrons create recoil protons, the protons activate a scintillator screen, the images can be collected with computer controlled CCD camera and the final picture can be saved on computer for the image processing. Experiments were carried out by using fast portative neutron generator Thermo Fischer MP320 at Çekmece Nuclear Research and Training Centre.Item VVER-1000 reaktöründe MCNP5/MONTEBURNS Monte Carlo kodları ile yanma oranı hesaplamaları(Türkiye Atom Enerjisi Kurumu, 2016) Özdemir, Levent; TAEK-ÇNAEM