Please use this identifier to cite or link to this item: http://kurumsalarsiv.tenmak.gov.tr/handle/20.500.12878/1689
Title: Effect of photon interaction depth in the determination of absolute efficiency of HPGe detector for liquid volume souce
Authors: Demirel, Halil
Yücel, Haluk
Çetiner, M. Atıf
Çetiner, B.
Yurtseven, İ.
Demircioğlu, Bengü
Karadeniz,Hande
Özmen, Atilla
TAEK-ANAEM
Keywords: HPGe detector
HPGe dedektörü
Liquid volume soruce
Sıvı hacim kaynağı
HPGe detector
HPGe dedektörü
Photon interaction depth
Foton etkileşim derinliği
Issue Date: 2003
Publisher: National Nuclear Center of the Republic of Kazakhstan / Institute of Nuclear Physics
Citation: Demirel, H. ... [ve arkadaşları]. (2003). A neutronic and thermal-hydraulic visual computer code for TR-2. The Second Eurasian Conference on Nuclear Science and Its Application : Presentations, 1.c., (s.202-215). 16-19 September 2002. Almaty : Kazakhstan.
Abstract: For practical measuring purposes in high pure Ge detectors, some useful semiempirical approaches are often used to calculate the peak efficiency (absolute efficiency) for any source-to-detector distance (d) if the efficiency has been measured at one known distance (d1). In all approaches considered, normally, one begins an experimental efficiency calibration for single measuring geometry at a distance (d1), and then derives the efficiency for any other arbitrary distance (d), from the relation ∈(d) = Ω (d) ∈(d1) = Ω (d1) where ∈ denotes the detector efficiency for any gamma ray energy and Ω is solid angle that is subtended by detector to the source position. However, this relation is only valid when the distances used in the relation was corrected for the effective photon interaction depth for any gamma-ray energy (Debertin and Helmer, 1988;Yücel et al.1996) since the efficiency ratio, ∈(d)/∈(d1), is not equal to the inverse ratio, d1-2/d-2. In the present work, the photon interaction depths depending upon gamma- ray energies in the range of about 50-2000 keV for point gamma sources (241Am, 137Cs, 60Co, 133Ba and 152Eu) and a liquid volume (cylindrical) source containing 57Co, 88Y, 113Sn, 137Cs, 109Cd, 139Ce and 60Co radionuclides were measured. Then, the calculation of the peak efficiency of a ptype HPGe detector is experimentally tested for both point and the extended (cylindrical) liquid source at various distances from the surface of the end cap of the detector by introduction of the effective photon interaction for any gamma-ray energy.
Description: TENMAK D.N.3326
URI: http://kurumsalarsiv.tenmak.gov.tr/handle/20.500.12878/1689
Appears in Collections:II. Eurasian conference nuclear science and its application : proceedings, 16-19 September, 2002. Almaty, Kazakhstan

Files in This Item:
File Description SizeFormat 
k80679.pdfYayıncı Sürümü286.2 kBAdobe PDFThumbnail
View/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.