dc.description.abstractIn the present work, effective atomic numbers (Zeff) of polypyrrole have been determined for total photon interactions at energy range 15.74 - 40.93 keV from the accurately measured total attenuation coefficients, by transmission method employing a good geometry setup for characteristic Ka and Kp X-rays of Zr, Mo, Ag, In, Sb, Ba and Pr. 59.54 keV gamma rays from 241 Am (100 mCi) source were used to excite the secondary targets. Characteristic X-rays of related elements after excited have been sent on polypyrrole using as target or absorber. Possible conclusions are compared with the theoretical ones obtained using the XCOM. The polypyrrole film has been directly formed on an aluminum plate by means of an anodization process. A Pt plate was used as the cathode. Anodization process was carried out under constant current conditions of I = 1mA. The polypyrrole/Al/polypyrrole structure was fabricated by an electrolyte being held at a constant temperature of 55 °C that was composed of 0.40 M pyrrole and 0.1 M tetrabutylammoniume tetrafluoroborate. The electrolyte solution was prepared in a propylene carbonate solvent (Merck). The polypyrrole has been coated on each side of aluminum plate. The area and thickness of the A1 plate are 1 cm2 and 0.012 cm, respectively.tr_TR
dc.identifier.citationErzeneoğlu, S. ... [ve arkadaşları]. (2006). Effective atomic numbers of polypyrrole via transmission method in the energy range 15.74-40.93 keV. The Fourth Eurasian Conference on Nuclear Science and Its Application : Presentations, (s. 549-555). 31 October-3 November 2006. Baku, Azerbaijan.tr_TR
dc.identifier.endpage555tr_TR
dc.identifier.startpage549tr_TR
dc.identifier.urihttp://kurumsalarsiv.tenmak.gov.tr/handle/20.500.12878/1130
dc.language.isoengtr_TR
dc.publisherAzerbaijan National Academy of Sciences Institute of Radiation Problems ve Turkish Atomic Energy Authoritytr_TR
dc.relation.journalThe Fourth Eurasian Conference on Nuclear Science and Its Application : Presentations, 31 October-3 November 2006. Baku, Azerbaijan.tr_TR
dc.rightsinfo:eu-repo/semantics/openAccesstr_TR
dc.subjectAtomic numbers of polypyrroletr_TR
dc.subjectPoliprolün atom sayılarıtr_TR
dc.subjectTransmission methodtr_TR
dc.subjectİletim yöntemitr_TR
dc.subjectEnergy range 15.74-40.93 keVtr_TR
dc.subject15.74-40.93 keV enerji aralığıtr_TR
dc.titleEffective atomic numbers of polypyrrole via transmission method in the energy range 15.74-40.93 keVtr_TR
dc.typeconferenceObjecttr_TR
Files
Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
k80380.pdf
Size:
538.19 KB
Format:
Adobe Portable Document Format
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.42 KB
Format:
Unknown data format
Description: