Gross alpha/beta measurements in water samples using liquid scintillation counter

dc.contributor.authorÇelebi, Nilgün
dc.contributor.authorYaşar, Sedat
dc.contributor.authorKarahan, Gürsel
dc.contributor.authorSönmez, Mehmet
dc.contributor.authorAkar, Bülent
dc.contributor.authorKoçak, Mehmet
dc.contributor.departmentTAEK-ÇNAEMtr_TR
dc.date.accessioned2018-07-30T12:25:53Z
dc.date.available2018-07-30T12:25:53Z
dc.date.issued2000-10
dc.descriptionI. Avrasya Nükleer Bilimler ve Uygulamaları Konferansı : 23-27 Ekim 2000. İzmir, Türkiye.tr_TR
dc.description.abstractLiquid scintillation techniques provide the detection and quantification of alpha and beta emitters in aqueous sample. Liquid Scintillation Counter (LSC) techniques using Pulse Decay Analysis (PDA) allow counting of alpha and beta radiation in the same sample simultaneously. PDA uses special pulse decay time discrimination electronics to differentiate alpha pulses from beta pulses in a liquid scintillator. In this experiment, Packard Tricarb 2770 TR-SL LSC has been used. Ultima Gold LLT produced by Packard Instrument Company was used as the liquid scintillator. The optimum counting parameters and Pulse Decay Discriminator (PDD) settings were provided for the best alpha and beta separation. PDD was verified by counting a pure alpha 241 Am and a pure beta 36C1. Spill of beta in alpha and alpha in beta was found around 0.1% at the optimum discriminator setting of 139. The counting efficiencies were 100% and 97% for alpha and beta counting respectively. Water samples were pre-concentrated to achieve the Turkish maximum permissible levels of 0.037 BqL -1 for gross alpha radioactivity and 0.37 BqL 1 for gross beta radioactivity in drinking water. After counting, the alpha and beta spill corrections were made and the gross alpha and beta radioactivities were calculated. LSC method results were compared with the gas flow proportional counters.tr_TR
dc.identifier.citationÇelebi, N. ... [ve arkadaşları]., (2000). Gross alpha/beta measurements in water samples using liquid scintillation counter. I. Eurasia Conference on Nuclear Science and Its Application, Presentations, Vol 1, (s. 507-512). 23-27 October 2000. İzmir, Turkey.tr_TR
dc.identifier.endpage512tr_TR
dc.identifier.startpage507tr_TR
dc.identifier.urihttp://kurumsalarsiv.tenmak.gov.tr/handle/20.500.12878/738
dc.language.isoengtr_TR
dc.publisherTurkish Atomic Energy Authoritytr_TR
dc.relation.journalI. Eurasia Conference on Nuclear Science and Its Application : Presentations, 23-27 October 2000. İzmir, Turkey.tr_TR
dc.rightsinfo:eu-repo/semantics/openAccesstr_TR
dc.subjectGross alpha/beta measurementstr_TR
dc.subjectBrüt alfa / beta ölçümleritr_TR
dc.subjectLiquid scintillation countertr_TR
dc.subjectSıvı sintilasyon sayacıtr_TR
dc.titleGross alpha/beta measurements in water samples using liquid scintillation countertr_TR
dc.typeconferenceObjecttr_TR
Files
Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
k80074.pdf
Size:
286.25 KB
Format:
Adobe Portable Document Format
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.42 KB
Format:
Unknown data format
Description: