Average glandular doses and national diagnostic reference levels in mammography examinations in Turkey

dc.contributor.authorParmaksız, Aydın
dc.contributor.authorAtaç, G. K.
dc.contributor.authorBulur, Emine
dc.contributor.authorİnal, Tolga
dc.contributor.authorAlhan, Aslıhan
dc.contributor.authorIDAAH-5187-2020en_US
dc.contributor.authorID0000-0003-4000-5175en_US
dc.contributor.departmentTAEK-Radyasyon ve Hızlandırıcı Teknolojileri Dairesi Başkanlığıen_US
dc.date.accessioned2021-04-01T07:34:26Z
dc.date.available2021-04-01T07:34:26Z
dc.date.issued2020-05
dc.description.abstractIn order to establish National Diagnostic Reference Levels (DRLs) for mammography examinations, Entrance Skin Air Kerma (ESAK), Entrance Skin Dose (ESD) and Average Glandular Doses (AGDs) were calculated for a total of 25624 cranio-caudal (CC) and mediolateral oblique (MLO) projections of 6309 patients for 40-49 and 50-64 age groups. The average ESAK and ESD values for both age groups were found to be higher in MLO projections compared to CC projections. The minimum and maximum values of AGDs were determined as 0.4 mGy and 7.9 mGy for both projections. The maximum numbers of AGDs for CC and MLO projections were calculated in the range of 1.1-1.5 mGy and 1.6-2.0 mGy respectively. The third quartile values of AGDs were calculated for each compressed breast thickness (CBT) between 20 mm and 99 mm. The first National DRLs of the country were established for each 10 mm CBT in mammography examinations.en_US
dc.identifier.citationParmaksız, A. ... [ve arkadaşları]. (2020). Average glandular doses and national diagnostic reference levels in mammography examinations in Turkey. Radiation Protection Dosimetry, 190(1), 100-107.en_US
dc.identifier.endpage107en_US
dc.identifier.issue1en_US
dc.identifier.startpage100en_US
dc.identifier.urihttps://academic.oup.com/rpd/article/190/1/100/5859089?searchresult=1
dc.identifier.urihttp://kurumsalarsiv.tenmak.gov.tr/handle/20.500.12878/1658
dc.identifier.volume190en_US
dc.language.isoengen_US
dc.publisherOxford University Pressen_US
dc.relation.isversionof10.1093/rpd/ncaa080en_US
dc.relation.journalRadiation Protection Dosimetryen_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectNational diagnostic reference levelsen_US
dc.subjectUlusal tanı referans seviyelerien_US
dc.subjectAverage glandular dosesen_US
dc.subjectOrtalama glandüler dozlaren_US
dc.subjectMammography examinations - Turkeyen_US
dc.subjectMamografi incelemeleri - Türkiyeen_US
dc.titleAverage glandular doses and national diagnostic reference levels in mammography examinations in Turkeyen_US
dc.typearticleen_US
Files
Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
60067.pdf
Size:
643.26 KB
Format:
Adobe Portable Document Format
Description:
Makale Sahibi Sürümü
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
3.36 KB
Format:
Item-specific license agreed upon to submission
Description: