Rapor 1970-1979 yılları
Permanent URI for this collection
Browse
Browsing Rapor 1970-1979 yılları by Language "eng"
Now showing 1 - 20 of 38
Results Per Page
Sort Options
Item A method for calculating plutonium source LMFBR accidents(T.A.E.C., Çekmece Nuclear Research And Training Center, 1975) Kırbıyık, M.; TAEK-ÇNAEMItem A modelled theory of pulsed-neutron experiments in fast subcritical assemblies(T.A.E.C., Çekmece Nuclear Research And Training Center, 1974) Adalıoğlu, Ulvi; Duderstadt, J. J.; TAEK-ÇNAEMThe time behavior of a neutron pulse in a fast subcritical assembly is modeled by approximating the spatial dependence by a single diffusion mode and using a simple model of inelastic scattering. This model allows an explicit calculation of the time response of a detector in such a system. Of particular interest is a study of the detector response in those situations in which the flux does not decay in an exponential fashion.Item A simple method of automatic optical transmission plotting(T.A.E.C., Çekmece Nuclear Research And Training Center, 1974) Ferendeci, A. M.; TAEK-ÇNAEMA simple electronic analog divider is described for plotting the transmittance or reflectance characteristics of optical materials as a function of wavelength. It is designed with commercially available integrated circuits and it automatically takes the ratio of any two signals connected to its inputs. The output is recorded as the spectrum is scanned by a monochromator.Item A switchboard between the computer and the teletype printer(T.A.E.C., Çekmece Nuclear Research And Training Center, 1977) Başol, Toygun S.; TAEK-ÇNAEMTandem Akselerator Laboratuarındaki OLDA on-line programı ile iletişim kurmak için mevcuda göre daha hızlı ve daha elverişli olan bir Switchboard'un tasarımı ve imali gerçekleştirildi. Switchboard, bilgisayar ile on-line uzak yazıcı (TTY) arasında yer alacak biçimde düşünülür. TTY kullanıldığında olağan 4 tuşla elde edilen komutlar, OLDA programında çok sık olan komutlardan bazıları için bir seçenek kaynak olan switchboard'da tek bir tuşun basılması ile sağlanır. Bundan başka, Switchboard'u kullanarak TTY nin "dışarıya basması" ile oluşan zaman kaybını beklemeksizin diğer bir komut gönderilir.Item An oil-water cooled linear magnet system(T.A.E.C., Çekmece Nuclear Research And Training Center, 1978) Subaşı, Metin; Tarcan, Gökçe; TAEK-ÇNAEMBurada özel yağ-su soğutmalı yedi ayrı, ortası oyuk silindir biçiminde (pancake) bobinlerden oluşan doğrusal (lineer) bir DC elektro-mıknatıs sistemi tanıtılmaktadır. Manyetik alan yoğunluğu 170 Gauss/A olup eldeki güç kaynağı (40V - 500A) ile erişilen en yüksek alan şiddeti 3 kGauss'tur. Bobinler arası uzaklık 4 cm alındığında 80 cm'lik bir bölgede elde edilen eksenel elan düzgünlüğü 4%' den daha iyidir.Item Application of the iodinated resin to the determination of thallium in biological samples by past neutron activation analysis(T. A. E. C., Çekmece Nuclear Research And Training Center, 1977) Okar, Sevim; Alkan, Meriç; TAEK-ÇNAEMBiyolojik maddelerdeki talyum tayini için basit, hızlı ve oldukça spesifik bir yöntem verilmiştir. Bu çalışmada, talyum tayinleri için hızlı nötron aktivasyon analizi ile iyotlandırılmış reçineler üzerinde ayırma tekniği birleştirilerek kullanılmıştır. Işınlanan örnekler, uygun soğuma sürelerinden sonra asitte çözülmüş ve bu çözeltiler, doymuş bir I(2)/KI çözeltisi ile muamele edilerek hazırlanmış anyon değiştirici reçine kolonundan geçirilmiştir. İyotlandırılmış reçinenin, Au(3+), Hg(2+) ve Ag(+) ile birlikte Tl(3+) iyonlarını da spesifik olarak tutma özelliği olduğu saptanmıştır. Bu tutulan iyonları taşıyan reçine, çok kanallı bir gamaspektrometresinde sayılmıştır. Tl(3+) iyonlarının reçine üzerinde % 98'in üzerinde bir verimlilikle tutulduğu görülmüştür. Hızlı nötron aktivasyon analizi ve iyotlandırılmış reçine üzerinde ayırma tekniğinin birleştirilmesi ile , ışınlama ve sayım için gereken soğuma süreleri ayarlanarak altın, cıva ve gümüşle birlikte olduğu zaman da biyolojik örneklerdeki talyum tayin edilebilmektedir.Item Chemical dosimeters in aqueous solutions(T.C. Başbakanlık Atom Enerjisi Komisyonu, Çekmece Nükleer Araştırma ve Eğitim Merkezi, 1972) Tuğsavul, Ayşen; Ünseren, Envare; TAEK-ÇNAEMItem Code of practice : On quality assurance for safety in nuclear power plants(Republic of Turkey Prime Ministry Atomic Energy Commission, 1978-12) TAEK; Republic of Turkey Prime Ministry Atomic Energy CommissionItem Comparison of 65 Zn Loss - Rate of mytilus gallaprovincialis determined in the field and laboratory conditions(T.A.E.C., Çekmece Nuclear Research And Training Center, 1974) Ünlü, M. Y.; TAEK-ÇNAEMWe have carried out experiments on the loss-rate of 65Zn by Mytilus galloprovincialis in the laboratory and in the field. We came to the conclusion that the results were obtained in the field and laboratory can be comparable if the physical and chemical conditions in the field are not changed very frequently.Item Determination of the toxic effect of AET on rat embryonic cells(T.C. Başbakanlık Atom Enerjisi Komisyonu, Çekmece Nükleer Araştırma ve Eğitim Merkezi, 1972) Üçer, Ertan; Bölükbaşı, Esin; TAEK-ÇNAEMBir radyasyon koruyucusu olan AET'nin, doku kültüründe yetiştirilen sıçan embriyo hücreleri üzerindeki, toksik tesiri tayin edilmiştir. 16 ilâ 45 mM konsantrasyonlarda kullanılan AETnin, sıçan embriyo hücreleri için toksik olmayan en yüksek dozunun 20mM öldürücü dozunun da 45 mM olduğu tesbit edilmiştir.Item Digital determination of TR-1 control rod worths and time behaviour of neutron flux(T.A.E.C., Çekmece Nuclear Research And Training Center, 1976) Ertek, Ç.; TAEK-ÇNAEMIn this work, the control rod reactivity worth of the swimming- pool type reactor (TR-I) in ÇNAEM, Çekmece Nuclear Research and Training Centre has been measured digitally and the mean neutron lifetime has been estimated by a special miniature fission chamber with 60 nanosecond resolving time. The time behaviour of thermal neutrons is also compared with reactor control console results.Item Exploration of radioactive minerals and recent developments(Turkish Atomic Energy Authority, Çekmece Nuclear Research And Training Center, 1978-03) İpekoğlu, B.; Erdine, H.; Uzmen, R.; TAEK-ÇNAEMItem High-field transport properties of aluminum-embedded aluminum oxide films(T.A.E.C., Çekmece Nuclear Research And Training Center, 1973) Birey, Hülya; TAEK-ÇNAEMCurrent-voltage characteristics of aluminum-embedded aluminum oxide thin films with Al or Au electrodes, between 150-1000 Â in thickness, prepared by thermic evaporation of pure aluminum in partial air pressure are studied. I - V characteristics of these films showed metallic conductivity, switching, and memory effects different than those observed in amorphous materials, and metal-oxide-metal diode characteristics as the amount of metallic aluminum within the oxide is decreased in respective samples. The switching and memory effects are found to be independent of oxide thickness and electrode material.Item Investigation of the aqueous glycine solution as a gamma-ray and neutron dosimeter(T.A.E.C., Çekmece Nuclear Research And Training Center, 1974) Tuğsavul, Ayşen; TAEK-ÇNAEMItem Linear extrapolation distances for centrally and eccentrically located control rods(T.C. Başbakanlık Atom Enerjisi Komisyonu, Çekmece Nükleer Araştırma ve Eğitim Merkezi, 1972) Borak, Fahir; TAEK-ÇNAEMUsing one-group diffusion theory, linear extrapolation distances for centrally and eccentrically located black control rods in cylindrical geometries have been determined by the pulsed neutron method. It is found that for a given radius control rod, the extrapolation distance increases with increasing moderator radius. Linear extrapolation distance is also found to increase with eccentrical location of control rods. In general, the values of the extrapolation distances determined for central rods in diffusion theory, in the range of moderator radii studied, are higher in value by 10 to 100% than the classical values based on the theoretical calculations of Davison and Zaretsky. The values of the linear extrapolation distances for eccentric control rods, in the range of the moderator radii studied, are also higher than the central control rod extrapolation distances up to a factor of 6, the increase depending on the location of the control rods.Item Metal film thickness measuring unit (micron meter)(T.C. Atom Enerjisi Komisyonu, Ankara Nükleer Araştırma Merkezi, 1970-07) Cockbaine, D. R.; TAEK-ANAEMThis report describes a simple unit to measure the metal film thickness evaporated on to a substrate. The method is perfectly general and will measure film thicknesses for 0,01 microns to 1 micron with metal specific resistances from 1,5 x 10 cm. to -6 Ω cm. to 500 x 10-6 Ω cm. Since the measuring device is contained within the evaporation unit, the evaporation process can be stopped whenever the desired film thickness has been reached.Item Metallic aluminum particle concentration in aluminum oxide thin films(T.A.E.C., Çekmece Nuclear Research And Training Center, 1974) Birey, H.; TAEK-ÇNAEMTwo different methods based on (a) the tunneling junction model and (b) the optical model are used to determine the metallic aluminum particle concentration in aluminum oxide thin films prepared by thermal evaporation of pure aluminum under appropriate vacuum conditions. The concentration determined from these two models agree with each other at high concentrations and show considerable deviation at low concentrations.Item On the numerical difference between homogeneous and heterogeneous calculations of uranium 238 capture rate ratios in light water reactors(T.A.E.C., Çekmece Nuclear Research And Training Center, 1975) Ertek, Ç.; Özbir, Yıldıray; TAEK-ÇNAEMItem Production of radioisotope 28Mg by (n, alpha) - (t, p) reaction at nuclear reactor(T.A.E.C., Çekmece Nuclear Research And Training Center, 1975) Gülbaba, T.; Gülbaba, G.; TAEK-ÇNAEMItem Radiation effect on the adiabatic compressibility of lubricating liquids(T.A.E.C., Çekmece Nuclear Research And Training Center., 1975) Yazgan, E.; TAEK-ÇNAEMMeasurements of sound wave velocity and density in four irradiated lubricating liquids have been made. From the measured velocity and density values adiabatic compressibities have been calculated.